{"id":22495,"date":"2023-03-30T01:02:21","date_gmt":"2023-03-29T17:02:21","guid":{"rendered":"https:\/\/university.segi.edu.my\/?p=22495"},"modified":"2023-11-08T11:32:49","modified_gmt":"2023-11-08T03:32:49","slug":"a-game-changer-for-precision-dentistry","status":"publish","type":"post","link":"https:\/\/university.segi.edu.my\/ms\/a-game-changer-for-precision-dentistry\/","title":{"rendered":"Pengubah permainan untuk pergigian ketepatan"},"content":{"rendered":"<p><span data-contrast=\"auto\">Fakulti Pergigian Universiti SEGi dengan sukacitanya mengumumkan pemasangan mesin CBCT baharu, model Dentium Rainbow, untuk menggantikan mesin Orthopantomogram (OPG) yang lebih lama. Dalam kes yang kompleks, mesin CBCT menjana imej tiga dimensi (3D) gigi, tisu lembut, laluan saraf dan tulang dalam satu imbasan, membolehkan perancangan rawatan yang lebih tepat.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">CBCT ialah sejenis mesin X-ray yang digunakan apabila X-ray pergigian standard tidak mencukupi. Cone beam CT digunakan untuk menilai penyakit rahang, gigi, struktur tulang muka, rongga hidung, dan sinus dengan memberikan imej terperinci tulang. Ia amat berguna untuk perancangan pembedahan untuk gigi impak, mendiagnosis gangguan sendi temporomandibular (TMJ), penempatan tepat implan pergigian, mengesan, mengukur dan merawat tumor rahang, menentukan struktur tulang dan orientasi gigi, analisis cephalometrik dan pembedahan rekonstruktif.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">CBCT telah menunjukkan ketepatan yang lebih tinggi dalam mengesan patologi periapikal, penyerapan akar, dan lesi apikal daripada radiografi pergigian tradisional, menurut data dari Persatuan Pergigian Amerika. Menurut Patel et al. (2020), penggunaan CBCT telah meningkatkan ketepatan peletakan implan dengan ketara dan mengurangkan risiko kegagalan implan.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Sebagai permulaan, beberapa kakitangan Fakulti menerima latihan pengguna daripada wakil Dentium Hassan pada 9 Mac 2023, dari 10 pagi hingga 11 pagi, di Fakulti Pergigian \u2013 jabatan Radiologi. Latihan pengenalan ini meliputi operasi mesin serta menangkap imej setempat (kecil), biasa (saiz sederhana), dan berjahit (muka penuh + tengkorak). Semasa sesi tersebut, para peserta juga diajar cara memanipulasi imej 3D menggunakan perisian. Semoga latihan pengenalan pengguna akan meningkatkan pemahaman tentang keupayaan mesin CBCT.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Selepas penentukuran dan servis yang diperlukan, mesin CBCT sedia untuk digunakan. Fakulti Pergigian di Universiti SEGi kini boleh menyediakan rawatan yang lebih tepat dan cekap kepada pesakitnya berkat teknologi baharu ini. Pelaburan dalam teknologi canggih ini bukan sahaja akan meningkatkan penjagaan pesakit tetapi juga akan meningkatkan tahap pendidikan pergigian di Malaysia.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Pemasangan mesin CBCT menunjukkan dedikasi Fakulti Pergigian untuk menyediakan teknologi termaju kepada pelajar, fakulti dan pesakitnya. Latihan pengguna ini hanyalah permulaan revolusi dalam pergigian ketepatan di Malaysia.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-full wp-image-22496\" src=\"http:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-4.jpg\" alt=\"\" width=\"949\" height=\"534\" srcset=\"https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-4.jpg 949w, https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-4-300x169.jpg 300w, https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-4-768x432.jpg 768w\" sizes=\"(max-width: 949px) 100vw, 949px\" \/> <img loading=\"lazy\" class=\"alignnone size-full wp-image-22497\" src=\"http:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-1.jpg\" alt=\"\" width=\"627\" height=\"470\" srcset=\"https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-1.jpg 627w, https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-1-300x225.jpg 300w\" sizes=\"(max-width: 627px) 100vw, 627px\" \/> <img loading=\"lazy\" class=\"alignnone size-full wp-image-22498\" src=\"http:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-3.jpg\" alt=\"\" width=\"1141\" height=\"642\" srcset=\"https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-3.jpg 1141w, https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-3-300x169.jpg 300w, https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-3-1024x576.jpg 1024w, https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-3-768x432.jpg 768w\" sizes=\"(max-width: 1141px) 100vw, 1141px\" \/> <img loading=\"lazy\" class=\"alignnone size-full wp-image-22499\" src=\"http:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-2.jpg\" alt=\"\" width=\"959\" height=\"720\" srcset=\"https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-2.jpg 959w, https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-2-300x225.jpg 300w, https:\/\/university.segi.edu.my\/wp-content\/uploads\/sites\/3\/2023\/04\/CBCT-2-768x577.jpg 768w\" sizes=\"(max-width: 959px) 100vw, 959px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>SEGi University&#8217;s Faculty of Dentistry is pleased to announce the installation of a new CBCT machine, the Dentium Rainbow model, to replace the older Orthopantomogram (OPG) machine. In complex cases, [&hellip;]<\/p>","protected":false},"author":39,"featured_media":22500,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[85,260,75],"tags":[],"_links":{"self":[{"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/posts\/22495"}],"collection":[{"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/users\/39"}],"replies":[{"embeddable":true,"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/comments?post=22495"}],"version-history":[{"count":5,"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/posts\/22495\/revisions"}],"predecessor-version":[{"id":26163,"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/posts\/22495\/revisions\/26163"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/media\/22500"}],"wp:attachment":[{"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/media?parent=22495"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/categories?post=22495"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/university.segi.edu.my\/ms\/wp-json\/wp\/v2\/tags?post=22495"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}