{"id":38785,"date":"2026-04-15T12:43:52","date_gmt":"2026-04-15T04:43:52","guid":{"rendered":"https:\/\/university.segi.edu.my\/?p=38785"},"modified":"2026-04-15T12:43:52","modified_gmt":"2026-04-15T04:43:52","slug":"thermomechanical-analysis-of-concrete-structures","status":"publish","type":"post","link":"https:\/\/university.segi.edu.my\/zh\/thermomechanical-analysis-of-concrete-structures\/","title":{"rendered":"\u6df7\u51dd\u571f\u7ed3\u6784\u7684\u70ed\u529b\u5b66\u5206\u6790"},"content":{"rendered":"<p data-start=\"0\" data-end=\"52\"><strong data-start=\"0\" data-end=\"52\">\u6df7\u51dd\u571f\u7ed3\u6784\u7684\u70ed\u529b\u5b66\u5206\u6790<\/strong><\/p>\n<p data-start=\"54\" data-end=\"504\">\u4e86\u89e3\u6df7\u51dd\u571f\u7ed3\u6784\u5728\u9ad8\u70ed\u4e0b\u7684\u54cd\u5e94\u5bf9\u4e8e\u63d0\u9ad8\u706b\u707e\u76f8\u5173\u4e8b\u4ef6\u540e\u7684\u5b89\u5168\u3001\u7ed3\u6784\u53ef\u9760\u6027\u548c\u6062\u590d\u89c4\u5212\u81f3\u5173\u91cd\u8981\u3002\u5728\u672c\u7814\u7a76\u4e2d\uff0c\u6765\u81ea\u5de5\u7a0b\u3001\u5efa\u7b51\u73af\u5883\u4e0e\u4fe1\u606f\u6280\u672f\u5b66\u9662\u7684 Ir. Ts. Dr. Tengku Anita, P.Eng(PEPC), MIEM, MSSA, MBOT \u8003\u5bdf\u4e86\u94a2\u7b4b\u6df7\u51dd\u571f\u5728 20\u00b0C \u81f3 800\u00b0C \u6e29\u5ea6\u8303\u56f4\u5185\u7684\u884c\u4e3a\uff0c\u5e76\u627f\u53d7\u4e86\u70ed\u548c\u673a\u68b0\u8054\u5408\u8f7d\u8377\u3002<\/p>\n<p data-start=\"506\" data-end=\"907\">\u901a\u8fc7\u7ed3\u5408\u5b9e\u9a8c\u5ba4\u6d4b\u8bd5\u548c\u5148\u8fdb\u7684\u6570\u503c\u6a21\u62df\uff0c\u8be5\u7814\u7a76\u6355\u6349\u4e86\u4e0a\u5347\u6e29\u5ea6\u5bf9\u94a2\u7b4b\u6df7\u51dd\u571f\u7684\u521a\u5ea6\u3001\u5f3a\u5ea6\u548c\u635f\u4f24\u884c\u4e3a\u7684\u5f71\u54cd\u3002\u8be5\u7814\u7a76\u4e3a\u6df7\u51dd\u571f\u5728\u4e25\u82db\u70ed\u529b\u6761\u4ef6\u4e0b\u6027\u80fd\u7684\u53d8\u5316\u65b9\u5f0f\u63d0\u4f9b\u4e86\u91cd\u8981\u89c1\u89e3\uff0c\u7279\u522b\u662f\u5f53\u7ed3\u6784\u6784\u4ef6\u5728\u66b4\u9732\u4e8e\u9ad8\u6e29\u7684\u540c\u65f6\u7ee7\u7eed\u627f\u8f7d\u65f6\u3002<\/p>\n<p data-start=\"909\" data-end=\"1392\">\u5f00\u53d1\u4e86\u4e00\u4e2a\u6e29\u5ea6\u6307\u6807\u7684\u6df7\u51dd\u571f\u635f\u4f24\u5851\u6027\u6a21\u578b\uff0c\u5e76\u8fdb\u884c\u4e86\u9ad8\u7cbe\u5ea6\u6821\u51c6\uff0cR\u00b2 \u503c\u7ea6\u4e3a 0.94\u3002\u7814\u7a76\u7ed3\u679c\u8868\u660e\uff0c\u94a2\u7b4b\u6df7\u51dd\u571f\u5728 500\u00b0C \u81f3 600\u00b0C \u4ee5\u4e0a\u4f1a\u8fc5\u901f\u52a3\u5316\uff0c\u968f\u7740\u6750\u6599\u7684\u5f31\u5316\uff0c\u635f\u4f24\u53d8\u5f97\u66f4\u52a0\u666e\u904d\uff0c\u9700\u8981\u66f4\u9ad8\u7684\u5e94\u53d8\u3002\u8fd9\u4e9b\u7ed3\u679c\u4e3a\u7406\u89e3\u6df7\u51dd\u571f\u7ed3\u6784\u5728\u6781\u7aef\u6761\u4ef6\u4e0b\u7684\u9000\u5316\u60c5\u51b5\u4ee5\u53ca\u5173\u952e\u9608\u503c\u7684\u51fa\u73b0\u63d0\u4f9b\u4e86\u66f4\u6e05\u6670\u7684\u8ba4\u8bc6\u3002<\/p>\n<p data-start=\"1394\" data-end=\"1767\">\u8fd9\u9879\u7814\u7a76\u901a\u8fc7\u652f\u6301\u5bf9\u6df7\u51dd\u571f\u7ed3\u6784\u706b\u707e\u66b4\u9732\u540e\u8fdb\u884c\u66f4\u53ef\u9760\u7684\u8bc4\u4f30\uff0c\u4e3a\u7ed3\u6784\u5de5\u7a0b\u9886\u57df\u505a\u51fa\u4e86\u5b9d\u8d35\u7684\u8d21\u732e\u3002\u5b83\u8fd8\u4e3a\u53c2\u4e0e\u7ed3\u6784\u4fee\u590d\u7684\u5de5\u7a0b\u5e08\u548c\u51b3\u7b56\u8005\u63d0\u4f9b\u4e86\u5b9e\u7528\u7684\u6307\u5bfc\uff0c\u6709\u52a9\u4e8e\u6539\u8fdb\u53d7\u635f\u5efa\u7b51\u7269\u548c\u57fa\u7840\u8bbe\u65bd\u7684\u8bc4\u4f30\u65b9\u6cd5\u548c\u6062\u590d\u7b56\u7565\u3002<\/p>\n<p data-start=\"1769\" data-end=\"1879\"><strong data-start=\"1769\" data-end=\"1786\">\u53d1\u8868\u4e8e\uff1a<\/strong> <em data-start=\"1787\" data-end=\"1831\">\u5de5\u7a0b\u4e0e\u5e94\u7528\u79d1\u5b66\u5b66\u62a5<\/em> <strong data-start=\"1832\" data-end=\"1846\">(Scopus 2)<\/strong><br data-start=\"1846\" data-end=\"1849\" \/><strong data-start=\"1849\" data-end=\"1863\">\u53d1\u884c\u5546<\/strong> \u65af\u666e\u6797\u683c\u00b7\u81ea\u7136<\/p>","protected":false},"excerpt":{"rendered":"<p>Thermomechanical Analysis of Concrete Structures Understanding how concrete structures respond to extreme heat is essential for improving safety, structural reliability, and recovery planning after fire related incidents. In this study, [&hellip;]<\/p>","protected":false},"author":47,"featured_media":38786,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[256,269,101,80,260,245,259,75,84],"tags":[],"_links":{"self":[{"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/posts\/38785"}],"collection":[{"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/comments?post=38785"}],"version-history":[{"count":1,"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/posts\/38785\/revisions"}],"predecessor-version":[{"id":38788,"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/posts\/38785\/revisions\/38788"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/media\/38786"}],"wp:attachment":[{"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/media?parent=38785"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/categories?post=38785"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/university.segi.edu.my\/zh\/wp-json\/wp\/v2\/tags?post=38785"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}